Moskit
1. PURPOSE
The purpose of the protective breakage detectors "MOSKIT", "MOSKIT-ST" (hereinafter referred to as the detector) is to detect intrusion of unauthorized people into protected territory, to protect cargoes during transportation and storage, to protect windows and doors, different fences, walls and etc.
2. GENERAL INFORMATION
2.1. The detector is activated when a thin barely visible double microwire is broken. The microwire is placed along the perimeter of a protected territory at a height of 0,5...0,7m and fixed at a distance of 3...10m on the available objects (posts, trees, bushes, etc.). To protect objects, windows, doors and fences the microwire is fixed on them so that the theft of the objects causes the breakage of the microwire.
2.2. A double microwire is pulled out of the case through a hole from the housing, the free end of the double microwire is closed by welding by a match or a lighter. After power supply is ON, the detector passes into standby control mode of the microwire integrity. When the microwire is broken, the detector is activated and starts generating an alarm. Therewith, in the “MOSKIT” detector a broken beep is ON; in the “MOSKIT-ST” the individual point relay contacts are broken and a light signal is ON. When power supply is below permissible norm the detector generates a continuous alarm.
2.3. The “MOSKIT” detector is supplied from a battery; the “MOSKIT-ST” detector is supplied from an external supply unit.
2.4. In the detector there is “PCN” output to connect to the central board using a plug-and-socket from the kit.
3. Distinctive Features
3.1. Small section and masking color of the double microwire provides its concealment and secrecy on the place.
3.2. The intruder can not define the moment when he enters a protected boundary because small efforts are required to break the microwire.
3.3. Efficiency Immediacy during organization or restoration of a protected boundary.
3.4. Possibility of connection to the central panel with a plug-and-socket included in the kit. The output is an “open collector” of an open transistor in the standby mode.
3.5. Small dimensions and weight.
3.6. Low price provides the availability of the detector to a wide range of customers.
4. Specifications
4.1. Minimal length of the microwire is 1500 m.
4.2. Supply voltage:
- “MOSKIT” - 12 V. The battery ALKALINE ALKABAT (AAA2/3) 12 V or similar one;
- “MOSKIT-ST” 12…30V (protection against power supply repolarization).
4.3. Maximum consumption current in the standby mode:
- “MOSKIT” - 0,025 mA;
- “MOSKIT-ST” - 10 mA.
4.4. Time of continuous work for “MOSKIT” detector in standby mode without battery replacement is 2…3 months.
5. Delivery Kit
Detector - 1 item;
Certificate - 1 item;
Spare coil (on order) - 1 item;
Case (on order) - 1 item;
Plug-and-socket intended for connection to the board - 1 item;